Zoom MultiStomp MIDISTOMP MIDI CCs & NRPNs

This is not the stock Zoom MultiStomp MIDI implementation. These CCs only work on an MS-50G, MS-60B or MS-70CDR running the MIDISTOMP custom firmware v1.2. Stock Zoom firmware ignores them. That's why the device is named "MultiStomp MIDISTOMP", and not after a single pedal model. The MIDISTOMP CCs follow the pedal's CC RECEIVE and MIDI CHANNEL settings (omni by default).

Last update: November 5, 2026 • 63 parameters


Contributions welcome! You can email us your edited CSV if you don't want to use GitHub.

Effect 1

Parameter CC Range Usage Description Orientation
Effect 1 on/off 14 [0–127]
0-63: Off; 64-127: On
Turns the effect in slot 1 of the current patch on or off.
Note: Requires the MIDISTOMP custom firmware (github.com/matujuice/zoom-ms-midistomp) v1.2 on an MS-50G, MS-60B or MS-70CDR. Stock Zoom firmware ignores this CC. Received on any channel unless the pedal's MIDI CHANNEL setting is set. CC RECEIVE must be on.
0-based
Effect 1 knob 1 15 [0–127]
0~127: Knob minimum to maximum
Parameter 1 of the effect in slot 1 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 1 knob 2 16 [0–127]
0~127: Knob minimum to maximum
Parameter 2 of the effect in slot 1 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 1 knob 3 17 [0–127]
0~127: Knob minimum to maximum
Parameter 3 of the effect in slot 1 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 1 knob 4 18 [0–127]
0~127: Knob minimum to maximum
Parameter 4 of the effect in slot 1 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 1 knob 5 19 [0–127]
0~127: Knob minimum to maximum
Parameter 5 of the effect in slot 1 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 1 knob 6 20 [0–127]
0~127: Knob minimum to maximum
Parameter 6 of the effect in slot 1 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 1 knob 7 21 [0–127]
0~127: Knob minimum to maximum
Parameter 7 of the effect in slot 1 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 1 knob 8 22 [0–127]
0~127: Knob minimum to maximum
Parameter 8 of the effect in slot 1 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 1 knob 9 23 [0–127]
0~127: Knob minimum to maximum
Parameter 9 of the effect in slot 1 of the current patch. The value is scaled across the knob's whole range.
0-based

Effect 2

Parameter CC Range Usage Description Orientation
Effect 2 on/off 24 [0–127]
0-63: Off; 64-127: On
Turns the effect in slot 2 of the current patch on or off.
0-based
Effect 2 knob 1 25 [0–127]
0~127: Knob minimum to maximum
Parameter 1 of the effect in slot 2 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 2 knob 2 26 [0–127]
0~127: Knob minimum to maximum
Parameter 2 of the effect in slot 2 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 2 knob 3 27 [0–127]
0~127: Knob minimum to maximum
Parameter 3 of the effect in slot 2 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 2 knob 4 28 [0–127]
0~127: Knob minimum to maximum
Parameter 4 of the effect in slot 2 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 2 knob 5 29 [0–127]
0~127: Knob minimum to maximum
Parameter 5 of the effect in slot 2 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 2 knob 6 30 [0–127]
0~127: Knob minimum to maximum
Parameter 6 of the effect in slot 2 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 2 knob 7 31 [0–127]
0~127: Knob minimum to maximum
Parameter 7 of the effect in slot 2 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 2 knob 8 32 [0–127]
0~127: Knob minimum to maximum
Parameter 8 of the effect in slot 2 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 2 knob 9 33 [0–127]
0~127: Knob minimum to maximum
Parameter 9 of the effect in slot 2 of the current patch. The value is scaled across the knob's whole range.
0-based

Effect 3

Parameter CC Range Usage Description Orientation
Effect 3 on/off 34 [0–127]
0-63: Off; 64-127: On
Turns the effect in slot 3 of the current patch on or off.
0-based
Effect 3 knob 1 35 [0–127]
0~127: Knob minimum to maximum
Parameter 1 of the effect in slot 3 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 3 knob 2 36 [0–127]
0~127: Knob minimum to maximum
Parameter 2 of the effect in slot 3 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 3 knob 3 37 [0–127]
0~127: Knob minimum to maximum
Parameter 3 of the effect in slot 3 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 3 knob 4 38 [0–127]
0~127: Knob minimum to maximum
Parameter 4 of the effect in slot 3 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 3 knob 5 39 [0–127]
0~127: Knob minimum to maximum
Parameter 5 of the effect in slot 3 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 3 knob 6 40 [0–127]
0~127: Knob minimum to maximum
Parameter 6 of the effect in slot 3 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 3 knob 7 41 [0–127]
0~127: Knob minimum to maximum
Parameter 7 of the effect in slot 3 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 3 knob 8 42 [0–127]
0~127: Knob minimum to maximum
Parameter 8 of the effect in slot 3 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 3 knob 9 43 [0–127]
0~127: Knob minimum to maximum
Parameter 9 of the effect in slot 3 of the current patch. The value is scaled across the knob's whole range.
0-based

Effect 4

Parameter CC Range Usage Description Orientation
Effect 4 on/off 44 [0–127]
0-63: Off; 64-127: On
Turns the effect in slot 4 of the current patch on or off.
0-based
Effect 4 knob 1 45 [0–127]
0~127: Knob minimum to maximum
Parameter 1 of the effect in slot 4 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 4 knob 2 46 [0–127]
0~127: Knob minimum to maximum
Parameter 2 of the effect in slot 4 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 4 knob 3 47 [0–127]
0~127: Knob minimum to maximum
Parameter 3 of the effect in slot 4 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 4 knob 4 48 [0–127]
0~127: Knob minimum to maximum
Parameter 4 of the effect in slot 4 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 4 knob 5 49 [0–127]
0~127: Knob minimum to maximum
Parameter 5 of the effect in slot 4 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 4 knob 6 50 [0–127]
0~127: Knob minimum to maximum
Parameter 6 of the effect in slot 4 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 4 knob 7 51 [0–127]
0~127: Knob minimum to maximum
Parameter 7 of the effect in slot 4 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 4 knob 8 52 [0–127]
0~127: Knob minimum to maximum
Parameter 8 of the effect in slot 4 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 4 knob 9 53 [0–127]
0~127: Knob minimum to maximum
Parameter 9 of the effect in slot 4 of the current patch. The value is scaled across the knob's whole range.
0-based

Effect 5

Parameter CC Range Usage Description Orientation
Effect 5 on/off 54 [0–127]
0-63: Off; 64-127: On
Turns the effect in slot 5 of the current patch on or off.
0-based
Effect 5 knob 1 55 [0–127]
0~127: Knob minimum to maximum
Parameter 1 of the effect in slot 5 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 5 knob 2 56 [0–127]
0~127: Knob minimum to maximum
Parameter 2 of the effect in slot 5 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 5 knob 3 57 [0–127]
0~127: Knob minimum to maximum
Parameter 3 of the effect in slot 5 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 5 knob 4 58 [0–127]
0~127: Knob minimum to maximum
Parameter 4 of the effect in slot 5 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 5 knob 5 59 [0–127]
0~127: Knob minimum to maximum
Parameter 5 of the effect in slot 5 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 5 knob 6 60 [0–127]
0~127: Knob minimum to maximum
Parameter 6 of the effect in slot 5 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 5 knob 7 61 [0–127]
0~127: Knob minimum to maximum
Parameter 7 of the effect in slot 5 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 5 knob 8 62 [0–127]
0~127: Knob minimum to maximum
Parameter 8 of the effect in slot 5 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 5 knob 9 63 [0–127]
0~127: Knob minimum to maximum
Parameter 9 of the effect in slot 5 of the current patch. The value is scaled across the knob's whole range.
0-based

Effect 6

Parameter CC Range Usage Description Orientation
Effect 6 on/off 64 [0–127]
0-63: Off; 64-127: On
Turns the effect in slot 6 of the current patch on or off.
0-based
Effect 6 knob 1 65 [0–127]
0~127: Knob minimum to maximum
Parameter 1 of the effect in slot 6 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 6 knob 2 66 [0–127]
0~127: Knob minimum to maximum
Parameter 2 of the effect in slot 6 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 6 knob 3 67 [0–127]
0~127: Knob minimum to maximum
Parameter 3 of the effect in slot 6 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 6 knob 4 68 [0–127]
0~127: Knob minimum to maximum
Parameter 4 of the effect in slot 6 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 6 knob 5 69 [0–127]
0~127: Knob minimum to maximum
Parameter 5 of the effect in slot 6 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 6 knob 6 70 [0–127]
0~127: Knob minimum to maximum
Parameter 6 of the effect in slot 6 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 6 knob 7 71 [0–127]
0~127: Knob minimum to maximum
Parameter 7 of the effect in slot 6 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 6 knob 8 72 [0–127]
0~127: Knob minimum to maximum
Parameter 8 of the effect in slot 6 of the current patch. The value is scaled across the knob's whole range.
0-based
Effect 6 knob 9 73 [0–127]
0~127: Knob minimum to maximum
Parameter 9 of the effect in slot 6 of the current patch. The value is scaled across the knob's whole range.
0-based

Patch

Parameter CC Range Usage Description Orientation
Previous patch 80 [0–127]
0-63: No action; 64-127: Previous patch
Loads the previous patch, wrapping from patch 1 to patch 50.
0-based
Next patch 81 [0–127]
0-63: No action; 64-127: Next patch
Loads the next patch, wrapping from patch 50 to patch 1.
0-based

Tuner

Parameter CC Range Usage Description Orientation
Tuner 74 [0–127]
0-63: Off; 64-127: On
Opens or closes the tuner.
Note: Stock Zoom behavior, kept by MIDISTOMP (it passes CCs it doesn't use to the stock handler).
0-based

This dataset is provided under the Creative Commons Attribution Share Alike 4.0 International license.