VERSION 1 ########################################################## # __ __ __ __ __ # # .--------|__|--| |__| .-----.--.--|__|--| |-----. # # | | | _ | |__| _ | | | | _ | -__| # # |__|__|__|__|_____|__|__|___ |_____|__|_____|_____| # # |_____| # # # ########################################################## # Generated on 2026-03-27 by https://midi.guide , the open, # 'comprehensive' dataset of all MIDI CCs and NRPNs. # Contributions welcome! # Supports all alphanumeric ASCII, and ' ', '_', '-', '+' - can also be NULL TRACKNAME AN1x # Can be POLY, DRUM, MPE, or NULL TYPE NULL # Can be A, B, C, D, USBD, USBH, CVGx (x between 1&4), CVx, Gx, or NULL OUTPORT NULL # Can be x (between 1-16), or NULL -- this is ignored if output port is not MIDI OUTCHAN NULL # Can be NONE, ALLACTIVE, A, B, USBH, USBD, CVG, or NULL INPORT NULL # Can be x (between 1-16), ALL, or NULL. This definition will be ignored if INPORT is NONE, ALLACTIVE or CVG INCHAN NULL # This defines the default 'MAX RATE' for automation lanes. # Can be NULL, 192, 96, 64, 48, 32, 24, 16, 12, 8, 6, 4, 3, 2, 1 MAXRATE NULL # DRUMLANES # Syntax: ROW:TRIG:CHAN:NOTENUMBER NAME # ROW must be between 1 and 8 # TRIG can be between 0 and 127, or NULL # CHAN can be a number between 1 and 16, Gx, CVx, CVGx (x between 1 and 4), or NULL # NOTENUMBER can be between 0 and 127, or NULL # NAME supports all alphanumeric ASCII, and ' ', '_', '-', '+' - can also be NULL # Please note this section will be discarded for tracks which are not DRUM tracks [DRUMLANES] [/DRUMLANES] # PC # Syntax: NUMBER NAME # number must be either: # - A number (for simple PC) # - Three numbers, delimited by ':', which represent PC:MSB:LSB. You can put 'NULL' to not set the MSB/LSB. # PC must be between 1...128 # MSB/LSB must be between 0...127 [PC] [/PC] # CC # Syntax: CC_NUMBER NAME or CC_NUMBER:DEFAULT=xx NAME # DEFAULT_VALUE must be a valid number between 0 and 127 [CC] 80 VCA Mod Depth 63 VCA Feedback Level 62 VCA Volume 73 Amp EG Attack 61 Amp EG Velocity Sensitivity 72 Amp EG Release 31 Amo EG Sustain Level 75 Amp EG Decay 58 VCF HPF Cutoff 30 VCF Cutoff Keyboard Track 19 VCF Filter Mod Depth 71 VCF Resonance Harmonic Content 74 VCF Cutoff Brightness 59 VCF Type 82 Filter EG Atack 29 Filter EG Release 28 Filter EG Sustain Level 83 Filter EG Decay 60 Filter EG Velocity Sensitivity 81 Filter EG Depth 94 Delay Depth 93 Chorus Variation Depth 91 Reverb Depth 7 Main Volume 10 Pan Position 3 Scene Select 8 Layer Mode 9 Poly Mono Mode 65 Portamento Switch 85 Portamento Mode 5 Portamento Time 64 Sustain Switch 1 Mod Wheel 11 Expression 4 Foot Controller 12 Ribbon Z Controller 13 Ribbon X Controller 90 Arpeggio Step Seq Switch 14 LFO Reset Mode 15 LFO 1 Wave 16 LFO 1 Speed 20 LFO 1 Delay 17 LFO 2 Speed 69 Mixer VCO 2 Level 70 Ring Modulator Level 39 Mixer Noise Level 68 Mixer VCO 1 Level 36 FM Source 1 35 FM Depth 34 VCO Sync Pitch Mod Switch 23 VCO Sync Pitch Depth 24 VCO Sync Pitch Source 22 VCO Sync Pitch 33 VCO Sync Algorithm 79 VCO 1 PWM Depth 86 VCO 1 PWM Source 78 VCO 1 Pulse Width 76 VCO 1 Edge 18 VCO 1 Pitch Mod Depth 50 VCO 1 Wave Type 87 VCO 2 PWM Source 55 VCO 2 Pulse Width 54 VCO 2 Edge 57 VCO 2 Pitch Mod Depth 53 VCO 2 Pitch Fine Tune 52 VCO 2 Pitch Coarse Tune 51 VCO 2 Wave Type 37 FM Source 2 77 VCO 1 Pitch Fine Tune 21 VCO 1 Pitch Coarse Tune 56 VCO 2 PWM Depth 27 PEG Decay 25 PEG Depth 26 PEG Switch [/CC] # CC Pair # Syntax: CC_MSB:CC_LSB NAME or CC_MSB:CC_LSB:DEFAULT=xx NAME # DEFAULT_VALUE must be a valid number between 0 and 16383 [CC_PAIR] [/CC_PAIR] # NRPN # Syntax: "MSB:LSB:DEPTH NAME" or "MSB:LSB:DEPTH:DEFAULT=xx NAME" # Lsb & msb should be between 0 and 127 # Note: LSB can be over 127 ONLY if MSB is 0 or omitted # e.g. '0:1026:7 FOO', or ':2000:7 BAR' # the examples above would be equivalent to '8:2:7 FOO' and '15:80:7 BAR' respectively # DEPTH can be 7 or 14 # For NRPN: DEFAULT_VALUE must be a valid number, either between 0 and 127 (for 7 bit NRPNs) or between 0 and 16383 (for 14bit NRPNs) [NRPN] [/NRPN] # ASSIGN # Syntax: POT_NUMBER TYPE:VALUE or POT_NUMBER TYPE:VALUE DEFAULT=DEFAULT_VALUE # POT_NUMBER must be between 1 and 8 # TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", "NRPN", or "NULL" (this won't assign the pot). # Non explicitly-defined pots will be considered "NULL" # VALUE VALIDATION #### For CC: Value must be a valid number between 0 and 119 #### For PB and AT, any text after the TYPE will be ignored #### For CV, value must be between 1 and 4 #### For NRPN, value must be MSB:LSB:DEPTH, with both lsb & msb bebtween 0 and 127, and DEPTH being either 7 or 14 # DEFAULT VALUE #### For CC: DEFAULT_VALUE must be a valid number between 0 and 127 #### For PB: DEFAULT_VALUE must be a valid number between 0 and 16383 #### For NRPN: DEFAULT_VALUE must be a valid number, either between 0 and 127 (for 7 bit NRPNs) or between 0 and 16383 (for 14bit NRPNs) #### For CV: DEFAULT_VALUE must be either a valid number between 0 and 65535, or a voltage between -5V and 5V, e.g. "-4.25V" or "1.7V" #### Please note default value will be ignored for PB and AT messages. [ASSIGN] [/ASSIGN] # AUTOMATION # Syntax: TYPE:VALUE # TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", or "NRPN" # VALUE VALIDATION #### For CC: Value must be a valid number between 0 and 119 #### For PB and AT, any text after the TYPE will be ignored #### For CV, value must be between 1 and 4 #### For NRPN, value must be MSB:LSB:DEPTH, with both lsb & msb bebtween 0 and 127, and DEPTH being either 7 or 14 # NOTE: You are limited to 64 automation lanes [AUTOMATION] [/AUTOMATION] # This section will be readable from Hapax. [COMMENT] [/COMMENT]