VERSION 1 ########################################################## # __ __ __ __ __ # # .--------|__|--| |__| .-----.--.--|__|--| |-----. # # | | | _ | |__| _ | | | | _ | -__| # # |__|__|__|__|_____|__|__|___ |_____|__|_____|_____| # # |_____| # # # ########################################################## # Generated for HapaxOS 3.22 on 2026-11-03 by https://midi.guide, # the open, 'comprehensive' dataset of all MIDI CCs and NRPNs. # Contributions welcome! # TRACKNAME ########### # Supports all alphanumeric ASCII, and ' ', '_', '-', '+'. Can also be NULL. TRACKNAME Super 6 # TYPE ###### # Can be POLY, DRUM, MPE, AFTR, POLYAT or NULL # POLY refers to polyphony, i.e. more than one note. Used for standard MIDI # gear and controllers. Confusingly, this is appropriate for instruments # and controllers that do not support poly aftertouch. # # POLYAT and AFTR are exchangeable, and both handle poly aftertouch as well as # channel aftertouch. TYPE NULL # OUTPORT ######### # Can be A, B, C, D, USBD, USBH, USBD[1-16] (virtual MIDI cable), # USBH[1-16] (virtual MIDI cable), CVG[1-4], CV[1-4], G[1-4], or NULL. OUTPORT NULL # OUTCHAN ######### # Can be a value between 1 and 16, or NULL. This is ignored if output port is # not MIDI. OUTCHAN NULL # INPORT ######## # Can be NONE, ALLACTIVE, A, B, C, D, USBD, USBH, USBD[1-16] (virtual MIDI # cable), USBH[1-16] (virtual MIDI cable), CVG[1-4], CV[1-4], G[1-4], or NULL. INPORT NULL # INCHAN ######## # Can be a value between 1 and 16, ALL, or NULL. This definition will be ignored # if INPORT is NONE, ALLACTIVE or CVG. INCHAN NULL # MAXRATE ######### # This defines the default MAXRATE for automation lanes. # Can be NULL, 192, 96, 64, 48, 32, 24, 16, 12, 8, 6, 4, 3, 2, 1 MAXRATE NULL # DRUMLANES ########### # Syntax: ROW:TRIG:CHAN:NOTENUMBER NAME # - ROW must be between 1 and 16 # - TRIG can be between 0 and 127, or NULL # - CHAN can be a number between 1 and 16, CVG[1-4], CV[1-4], G[1-4], or NULL # - NOTENUMBER can be between 0 and 127, or NULL # - NAME supports all alphanumeric ASCII, and ' ', '_', '-', '+'. It can # also be NULL # # This section will be discarded for tracks which are not DRUM tracks. [DRUMLANES] [/DRUMLANES] # PC #### # Syntax: NUMBER NAME # - NUMBER must be either a number (for simple PC), or three numbers, # delimited by ':', which represent PC:MSB:LSB. You can put 'NULL' # to not set the MSB/LSB # - PC must be between 1...128 # - MSB and LSB, if set, must be between 0...127 [PC] [/PC] # CC #### # Syntax: CC_NUMBER NAME or CC_NUMBER:DEFAULT=xx NAME # - DEFAULT_VALUE must be between 0 and 127 [CC] 82 Arp range 90 Seq length 89 Seq rec mode 87 Hold 86 Arp or seq on 85 Arp or seq mode 83 Arp or seq swing 15 Chorus II on 14 Chorus I on 22 DDS Env 1 amount 23 DDS modulator destination 21 DDS LFO 1 amount 76 DDS pitch bend amt 30 DDS 1 range 31 DDS 2 waveform 34 DDS 2 range 35 DDS 2 tune 70 DDS LFO 2 amt 36 DDS 2 mode 29 DDS 1 waveform 12 Delay time 91 Delay level 13 Delay feedback 57 Env 2 decay 55 Env 1 sustain 54 Env 1 decay 53 Env 1 attack 52 Env 1 hold 51 Env 1 keytrack 50 Env 1 mode 73 Env 2 attack 72 Env 2 release 58 Env 2 sustain 56 Env 1 release 127 Poly mode on 1 Modulation lever 3 Tempo 4 Foot controller 5 Portamento time 6 Data entry MSB 38 LSB for Control 6 data entry 59 Manual 61 Performance control dest 64 Sustain pedal 96 Data increment 97 Data decrement 98 NRPN LSB 99 NRPN MSB 100 RPN LSB 101 RPN MSB 120 All sound off 121 Reset all controllers 122 Local control on off 123 All notes off 124 Omni mode off 125 Omni mode on 126 Mono mode on 16 LFO 1 waveform HF mode 62 LFO 2 rate 20 LFO 1 mode 19 LFO 1 L R phase 18 LFO 1 delay 17 LFO 1 rate 63 LFO 2 delay 60 LFO 2 trigger src 24 Super mode 28 Cross mod 27 PWM SWM src 37 Ocsillator Mix split point 26 PWM SWM 78 Voice assign mode 79 Union size 80 Binaural mode on 81 Sync 25 PW Detune 49 VCA env mode 48 VCA dynamics 7 VCA env level 44 VCF env src 43 VCF keytrack 41 VCF drive 40 VCF HPF mode 46 VCF LFO 1 amt 47 VCF LFO 2 amt 71 VCF resonance 77 VCF pitch bend amt 75 VCF LFO 2 amt 92 VCF LFO 1 amt 74 VCF cutoff frequency 45 VCF env amt [/CC] # CC_PAIR ######### # Syntax: CC_MSB:CC_LSB NAME or CC_MSB:CC_\LSB:DEFAULT=xx NAME # - DEFAULT_VALUE must be between 0 and 16383 [CC_PAIR] [/CC_PAIR] # NRPN ###### # Syntax: MSB:LSB:DEPTH NAME or MSB:LSB:DEPTH:DEFAULT=xx NAME # - MSB and LSB should be between 0 and 127 # - LSB can be over 127 ONLY if MSB is either 0 or omitted. For example: # "0:1026:7 FOO" or ":2000:7 BAR" # These examples are equivalent to "8:2:7 FOO" and "15:80:7 BAR" # - DEPTH can be 7 or 14 # - DEFAULT_VALUE must be between 0 and 127 (for 7-bit NRPNs) or # between 0 and 16383 (for 14-bit NRPNs) [NRPN] [/NRPN] # ASSIGN ######## # Syntax: POT_NUMBER TYPE:VALUE or POT_NUMBER TYPE:VALUE DEFAULT=DEFAULT_VALUE # - POT_NUMBER must be between 1 and 8 # - TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", "NRPN", # or "NULL" (this won't assign the pot) # - Non explicitly-defined pots will be considered "NULL" # # VALUE validation # - CC: VALUE must be a valid number between 0 and 119 # - PB and AT: Any text after the TYPE will be ignored # - CV: VALUE must be between 1 and 4 # - NRPN: VALUE must be MSB:LSB:DEPTH, with MSB and LSB between 0 and 127, # and DEPTH either 7 or 14 # # DEFAULT_VALUE # - CC: DEFAULT_VALUE must be between 0 and 127 # - PB: DEFAULT_VALUE must be between 0 and 16383 # - NRPN: DEFAULT_VALUE must be a number between 0 and 127 (for 7-bit NRPNs) # or between 0 and 16383 (for 14-bit NRPNs) # - CV: DEFAULT_VALUE must be either between 0 and 65535, or a voltage between # -5V and 5V, e.g. "-4.25V" or "1.7V" # # DEFAULT_VALUE will be ignored for PB and AT messages. [ASSIGN] [/ASSIGN] # AUTOMATION ############ # Syntax: TYPE:VALUE # - TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", or "NRPN" # # VALUE validation # - CC: VALUE must be between 0 and 119 # - PB and AT: Any text after the TYPE will be ignored # - CV: VALUE must be between 1 and 4 # - NRPN: VALUE must be MSB:LSB:DEPTH, with MSB and LSB between 0 and 127, # and DEPTH either 7 or 14 # # You are limited to 64 automation lanes. [AUTOMATION] [/AUTOMATION] # COMMENT ######### # This section will be readable from Hapax. [COMMENT] [/COMMENT]