VERSION 1 # Supports all alphanumeric ASCII, and ' ', '_', '-', '+' - can also be NULL TRACKNAME MEGAfm # Can be POLY, DRUM, MPE, or NULL TYPE NULL # Can be A, B, C, D, USBD, USBH, CVGx (x between 1&4), CVx, Gx, or NULL OUTPORT NULL # Can be x (between 1-16), or NULL -- this is ignored if output port is not MIDI OUTCHAN NULL # Can be NONE, ALLACTIVE, A, B, USBH, USBD, CVG, or NULL INPORT NULL # Can be x (between 1-16), ALL, or NULL. This definition will be ignored if INPORT is NONE, ALLACTIVE or CVG INCHAN NULL # This defines the default 'MAX RATE' for automation lanes. # Can be NULL, 192, 96, 64, 48, 32, 24, 16, 12, 8, 6, 4, 3, 2, 1 MAXRATE NULL # DRUMLANES # Syntax: ROW:TRIG:CHAN:NOTENUMBER NAME # ROW must be between 1 and 8 # TRIG can be between 0 and 127, or NULL # CHAN can be a number between 1 and 16, Gx, CVx, CVGx (x between 1 and 4), or NULL # NOTENUMBER can be between 0 and 127, or NULL # NAME supports all alphanumeric ASCII, and ' ', '_', '-', '+' - can also be NULL # Please note this section will be discarded for tracks which are not DRUM tracks [DRUMLANES] [/DRUMLANES] # PC # Syntax: NUMBER NAME # number must be either: # - A number (for simple PC) # - Three numbers, delimited by ':', which represent PC:MSB:LSB. You can put 'NULL' to not set the MSB/LSB. # PC must be between 1...128 # MSB/LSB must be between 0...127 [PC] [/PC] # CC # Syntax: CC_NUMBER NAME or CC_NUMBER:DEFAULT=xx NAME # DEFAULT_VALUE must be a valid number between 0 and 127 [CC] 6 Arp rate 5 Arp range 4 FM algorithm 28 Fat 3 Feedback 12 LFO1 depth 15 LFO1 rate 14 LFO3 rate 9 LFO2 depth 10 LFO2 rate 2 LFO3 depth 17 Op1 sustain rate 18 Op1 detune 25 Op1 sustain level 27 Op1 multiplier 29 Op1 attack rate 21 Op1 decay rate 30 Op1 release rate 31 Op2 detune 36 Op2 attack rate 44 Op2 decay rate 42 Op2 sustain level 34 Op2 sustain rate 11 Op2 release rate 32 Op2 multiplier 50 Op3 decay rate 20 Op3 detune 24 Op3 multiplier 49 Op3 attack rate 51 Op3 sustain level 45 Op3 sustain rate 37 Op3 release rate 35 Op4 release rate 43 Op4 sustain rate 41 Op4 sustain level 33 Op4 decay rate 46 Op4 attack rate 39 Op4 multiplier 47 Op4 detune 48 Vibrato rate 13 Vibrato depth [/CC] # CC Pair # Syntax: CC_MSB:CC_LSB NAME or CC_MSB:CC_LSB:DEFAULT=xx NAME # DEFAULT_VALUE must be a valid number between 0 and 16383 [CC_PAIR] [/CC_PAIR] # NRPN # Syntax: "MSB:LSB:DEPTH NAME" or "MSB:LSB:DEPTH:DEFAULT=xx NAME" # Lsb & msb should be between 0 and 127 # Note: LSB can be over 127 ONLY if MSB is 0 or omitted # e.g. '0:1026:7 FOO', or ':2000:7 BAR' # the examples above would be equivalent to '8:2:7 FOO' and '15:80:7 BAR' respectively # DEPTH can be 7 or 14 # For NRPN: DEFAULT_VALUE must be a valid number, either between 0 and 127 (for 7 bit NRPNs) or between 0 and 16383 (for 14bit NRPNs) [NRPN] [/NRPN] # ASSIGN # Syntax: POT_NUMBER TYPE:VALUE or POT_NUMBER TYPE:VALUE DEFAULT=DEFAULT_VALUE # POT_NUMBER must be between 1 and 8 # TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", "NRPN", or "NULL" (this won't assign the pot). # Non explicitly-defined pots will be considered "NULL" # VALUE VALIDATION #### For CC: Value must be a valid number between 0 and 119 #### For PB and AT, any text after the TYPE will be ignored #### For CV, value must be between 1 and 4 #### For NRPN, value must be MSB:LSB:DEPTH, with both lsb & msb bebtween 0 and 127, and DEPTH being either 7 or 14 # DEFAULT VALUE #### For CC: DEFAULT_VALUE must be a valid number between 0 and 127 #### For PB: DEFAULT_VALUE must be a valid number between 0 and 16383 #### For NRPN: DEFAULT_VALUE must be a valid number, either between 0 and 127 (for 7 bit NRPNs) or between 0 and 16383 (for 14bit NRPNs) #### For CV: DEFAULT_VALUE must be either a valid number between 0 and 65535, or a voltage between -5V and 5V, e.g. "-4.25V" or "1.7V" #### Please note default value will be ignored for PB and AT messages. [ASSIGN] [/ASSIGN] # AUTOMATION # Syntax: TYPE:VALUE # TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", or "NRPN" # VALUE VALIDATION #### For CC: Value must be a valid number between 0 and 119 #### For PB and AT, any text after the TYPE will be ignored #### For CV, value must be between 1 and 4 #### For NRPN, value must be MSB:LSB:DEPTH, with both lsb & msb bebtween 0 and 127, and DEPTH being either 7 or 14 # NOTE: You are limited to 64 automation lanes [AUTOMATION] [/AUTOMATION] # This section will be readable from Hapax. [COMMENT] [/COMMENT]