VERSION 1 # Supports all alphanumeric ASCII, and ' ', '_', '-', '+' - can also be NULL TRACKNAME D-TWO # Can be POLY, DRUM, MPE, or NULL TYPE NULL # Can be A, B, C, D, USBD, USBH, CVGx (x between 1&4), CVx, Gx, or NULL OUTPORT NULL # Can be x (between 1-16), or NULL -- this is ignored if output port is not MIDI OUTCHAN NULL # Can be NONE, ALLACTIVE, A, B, USBH, USBD, CVG, or NULL INPORT NULL # Can be x (between 1-16), ALL, or NULL. This definition will be ignored if INPORT is NONE, ALLACTIVE or CVG INCHAN NULL # This defines the default 'MAX RATE' for automation lanes. # Can be NULL, 192, 96, 64, 48, 32, 24, 16, 12, 8, 6, 4, 3, 2, 1 MAXRATE NULL # DRUMLANES # Syntax: ROW:TRIG:CHAN:NOTENUMBER NAME # ROW must be between 1 and 8 # TRIG can be between 0 and 127, or NULL # CHAN can be a number between 1 and 16, Gx, CVx, CVGx (x between 1 and 4), or NULL # NOTENUMBER can be between 0 and 127, or NULL # NAME supports all alphanumeric ASCII, and ' ', '_', '-', '+' - can also be NULL # Please note this section will be discarded for tracks which are not DRUM tracks [DRUMLANES] [/DRUMLANES] # PC # Syntax: NUMBER NAME # number must be either: # - A number (for simple PC) # - Three numbers, delimited by ':', which represent PC:MSB:LSB. You can put 'NULL' to not set the MSB/LSB. # PC must be between 1...128 # MSB/LSB must be between 0...127 [PC] [/PC] # CC # Syntax: CC_NUMBER NAME or CC_NUMBER:DEFAULT=xx NAME # DEFAULT_VALUE must be a valid number between 0 and 127 [CC] 16 IN LVL 17 DIG IN LVL 18 OUT LVL 19 MIX LVL 20 Bypass 21 REV Offst 22 Spatial 23 Filter 24 Chorus 25 Reverse 26 Dynamic 27 Ping Pong 28 Rhythm 48 Delay 50 FB LVL 51 FB Repeats 52 Shuffle 53 Quantize 54 Tracktap 55 Rhytm DEC 56 Subdiv 57 FX LVL 58 Spatl Offst 59 Spatl Phserev 60 FB Hicut 61 FB Locut 62 Hicut 63 Locut 64 Chrs SPD 65 Chrs Dpth 66 Chrs AMT 67 Chrs Fdbk 68 Chrs Time 69 Chrs Gold Rtio 70 Chrs Phse REV 71 Chrs LFO Curv 72 Chrs LFO Phse 73 Pingstyle 74 Threshold 75 Release 76 Damping 77 REV Thrshld 78 REV Style [/CC] # CC Pair # Syntax: CC_MSB:CC_LSB NAME or CC_MSB:CC_LSB:DEFAULT=xx NAME # DEFAULT_VALUE must be a valid number between 0 and 16383 [CC_PAIR] [/CC_PAIR] # NRPN # Syntax: "MSB:LSB:DEPTH NAME" or "MSB:LSB:DEPTH:DEFAULT=xx NAME" # Lsb & msb should be between 0 and 127 # Note: LSB can be over 127 ONLY if MSB is 0 or omitted # e.g. '0:1026:7 FOO', or ':2000:7 BAR' # the examples above would be equivalent to '8:2:7 FOO' and '15:80:7 BAR' respectively # DEPTH can be 7 or 14 # For NRPN: DEFAULT_VALUE must be a valid number, either between 0 and 127 (for 7 bit NRPNs) or between 0 and 16383 (for 14bit NRPNs) [NRPN] [/NRPN] # ASSIGN # Syntax: POT_NUMBER TYPE:VALUE or POT_NUMBER TYPE:VALUE DEFAULT=DEFAULT_VALUE # POT_NUMBER must be between 1 and 8 # TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", "NRPN", or "NULL" (this won't assign the pot). # Non explicitly-defined pots will be considered "NULL" # VALUE VALIDATION #### For CC: Value must be a valid number between 0 and 119 #### For PB and AT, any text after the TYPE will be ignored #### For CV, value must be between 1 and 4 #### For NRPN, value must be MSB:LSB:DEPTH, with both lsb & msb bebtween 0 and 127, and DEPTH being either 7 or 14 # DEFAULT VALUE #### For CC: DEFAULT_VALUE must be a valid number between 0 and 127 #### For PB: DEFAULT_VALUE must be a valid number between 0 and 16383 #### For NRPN: DEFAULT_VALUE must be a valid number, either between 0 and 127 (for 7 bit NRPNs) or between 0 and 16383 (for 14bit NRPNs) #### For CV: DEFAULT_VALUE must be either a valid number between 0 and 65535, or a voltage between -5V and 5V, e.g. "-4.25V" or "1.7V" #### Please note default value will be ignored for PB and AT messages. [ASSIGN] [/ASSIGN] # AUTOMATION # Syntax: TYPE:VALUE # TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", or "NRPN" # VALUE VALIDATION #### For CC: Value must be a valid number between 0 and 119 #### For PB and AT, any text after the TYPE will be ignored #### For CV, value must be between 1 and 4 #### For NRPN, value must be MSB:LSB:DEPTH, with both lsb & msb bebtween 0 and 127, and DEPTH being either 7 or 14 # NOTE: You are limited to 64 automation lanes [AUTOMATION] [/AUTOMATION] # This section will be readable from Hapax. [COMMENT] [/COMMENT]