VERSION 1 ########################################################## # __ __ __ __ __ # # .--------|__|--| |__| .-----.--.--|__|--| |-----. # # | | | _ | |__| _ | | | | _ | -__| # # |__|__|__|__|_____|__|__|___ |_____|__|_____|_____| # # |_____| # # # ########################################################## # Generated for HapaxOS 3.22 on 2026-11-04 by https://midi.guide, # the open, 'comprehensive' dataset of all MIDI CCs and NRPNs. # Contributions welcome! # TRACKNAME ########### # Supports all alphanumeric ASCII, and ' ', '_', '-', '+'. Can also be NULL. TRACKNAME JD-XA # TYPE ###### # Can be POLY, DRUM, MPE, AFTR, POLYAT or NULL # POLY refers to polyphony, i.e. more than one note. Used for standard MIDI # gear and controllers. Confusingly, this is appropriate for instruments # and controllers that do not support poly aftertouch. # # POLYAT and AFTR are exchangeable, and both handle poly aftertouch as well as # channel aftertouch. TYPE NULL # OUTPORT ######### # Can be A, B, C, D, USBD, USBH, USBD[1-16] (virtual MIDI cable), # USBH[1-16] (virtual MIDI cable), CVG[1-4], CV[1-4], G[1-4], or NULL. OUTPORT NULL # OUTCHAN ######### # Can be a value between 1 and 16, or NULL. This is ignored if output port is # not MIDI. OUTCHAN NULL # INPORT ######## # Can be NONE, ALLACTIVE, A, B, C, D, USBD, USBH, USBD[1-16] (virtual MIDI # cable), USBH[1-16] (virtual MIDI cable), CVG[1-4], CV[1-4], G[1-4], or NULL. INPORT NULL # INCHAN ######## # Can be a value between 1 and 16, ALL, or NULL. This definition will be ignored # if INPORT is NONE, ALLACTIVE or CVG. INCHAN NULL # MAXRATE ######### # This defines the default MAXRATE for automation lanes. # Can be NULL, 192, 96, 64, 48, 32, 24, 16, 12, 8, 6, 4, 3, 2, 1 MAXRATE NULL # DRUMLANES ########### # Syntax: ROW:TRIG:CHAN:NOTENUMBER NAME # - ROW must be between 1 and 16 # - TRIG can be between 0 and 127, or NULL # - CHAN can be a number between 1 and 16, CVG[1-4], CV[1-4], G[1-4], or NULL # - NOTENUMBER can be between 0 and 127, or NULL # - NAME supports all alphanumeric ASCII, and ' ', '_', '-', '+'. It can # also be NULL # # This section will be discarded for tracks which are not DRUM tracks. [DRUMLANES] [/DRUMLANES] # PC #### # Syntax: NUMBER NAME # - NUMBER must be either a number (for simple PC), or three numbers, # delimited by ':', which represent PC:MSB:LSB. You can put 'NULL' # to not set the MSB/LSB # - PC must be between 1...128 # - MSB and LSB, if set, must be between 0...127 [PC] [/PC] # CC #### # Syntax: CC_NUMBER NAME or CC_NUMBER:DEFAULT=xx NAME # - DEFAULT_VALUE must be between 0 and 127 [CC] 1 Modulation 2 OSC2 PWM 4 OSC2 PW 5 Portamento Time 7 Volume 10 Panpot 11 Expression 12 Reverb Level 13 Delay Level 14 TFX1 Control 15 TFX2 Control 16 LFO1 Rate 17 LFO2 Rate 18 LFO3 Rate 19 OSC1 Pitch 20 OSC2 Pitch 21 OSC3 Pitch 22 OSC1 Fine 23 OSC2 Fine 24 OSC3 Fine 25 OSC1 Cross MOD 26 OSC1 P ENV Depth 27 OSC2 P ENV Depth 28 OSC3 P ENV Depth 29 OSC1 Level 30 OSC2 Level 31 AUX Level 64 Hold 65 Portamento 70 Atck Pitch ENV 71 Resonance 72 Release Time 73 Attack Time 74 Cutoff 75 Decay Time 76 Vibrato Rate 77 Vibrato Depth 78 Vibrato Delay 80 TFX1 Select 81 TFX2 Select 82 Delay Time 83 MIC Level 91 TFX Reverb Send LEV 92 LFO Pitch Depth 93 LFO Filter Depth 94 LFO AMP Depth 95 Decay Pitch ENV 98 Nrpn MSB 99 Nrpn LSB 100 RPN MSB 101 RPN LSB 102 OSC1 Cutoff 103 Cutoff Fine OSC2 Cutoff 104 OSC3 Cutoff 105 OSC1 Resonance 106 OSC2 Resonance 107 OSC3 Resonance 108 OSC1 Filt ENV Depth 109 OSC2 Filt ENV Depth 110 OSC3 Filt ENV Depth 111 OSC1 KEY Follow 112 OSC2 KEY Follow Fine 113 OSC3 KEY Follow 114 OSC1 HPF Cutoff 115 Drive OSC2 HPF Cutoff 116 OSC3 HPF Cutoff 117 AMP Level 120 ALL Sound OFF 121 Reset ALL Controllers 122 Local ON OFF 123 ALL Notes OFF 124 Omni OFF 125 Omni ON 126 Mono 127 Poly [/CC] # CC_PAIR ######### # Syntax: CC_MSB:CC_LSB NAME or CC_MSB:CC_\LSB:DEFAULT=xx NAME # - DEFAULT_VALUE must be between 0 and 16383 [CC_PAIR] [/CC_PAIR] # NRPN ###### # Syntax: MSB:LSB:DEPTH NAME or MSB:LSB:DEPTH:DEFAULT=xx NAME # - MSB and LSB should be between 0 and 127 # - LSB can be over 127 ONLY if MSB is either 0 or omitted. For example: # "0:1026:7 FOO" or ":2000:7 BAR" # These examples are equivalent to "8:2:7 FOO" and "15:80:7 BAR" # - DEPTH can be 7 or 14 # - DEFAULT_VALUE must be between 0 and 127 (for 7-bit NRPNs) or # between 0 and 16383 (for 14-bit NRPNs) [NRPN] 0:3:7 P1 LFO Shape 0:4:7 P2 LFO Shape 0:5:7 P3 LFO Shape 0:15:7 P1 LFO Pitch Depth 0:16:7 P2 LFO Pitch Depth 0:17:7 P3 LFO Pitch Depth 0:18:7 P1 LFO Filter Depth 0:19:7 P2 LFO Filter Depth 0:20:7 P3 LFO Filter Depth 0:21:7 P1 LFO AMP Depth 0:22:7 P2 LFO AMP Depth 0:23:7 P3 LFO AMP Depth 0:37:7 Analog Pulse Width 0:124:7 P1 Envelope 0:125:7 P2 Envelope 0:126:7 P3 Envelope [/NRPN] # ASSIGN ######## # Syntax: POT_NUMBER TYPE:VALUE or POT_NUMBER TYPE:VALUE DEFAULT=DEFAULT_VALUE # - POT_NUMBER must be between 1 and 8 # - TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", "NRPN", # or "NULL" (this won't assign the pot) # - Non explicitly-defined pots will be considered "NULL" # # VALUE validation # - CC: VALUE must be a valid number between 0 and 119 # - PB and AT: Any text after the TYPE will be ignored # - CV: VALUE must be between 1 and 4 # - NRPN: VALUE must be MSB:LSB:DEPTH, with MSB and LSB between 0 and 127, # and DEPTH either 7 or 14 # # DEFAULT_VALUE # - CC: DEFAULT_VALUE must be between 0 and 127 # - PB: DEFAULT_VALUE must be between 0 and 16383 # - NRPN: DEFAULT_VALUE must be a number between 0 and 127 (for 7-bit NRPNs) # or between 0 and 16383 (for 14-bit NRPNs) # - CV: DEFAULT_VALUE must be either between 0 and 65535, or a voltage between # -5V and 5V, e.g. "-4.25V" or "1.7V" # # DEFAULT_VALUE will be ignored for PB and AT messages. [ASSIGN] [/ASSIGN] # AUTOMATION ############ # Syntax: TYPE:VALUE # - TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", or "NRPN" # # VALUE validation # - CC: VALUE must be between 0 and 119 # - PB and AT: Any text after the TYPE will be ignored # - CV: VALUE must be between 1 and 4 # - NRPN: VALUE must be MSB:LSB:DEPTH, with MSB and LSB between 0 and 127, # and DEPTH either 7 or 14 # # You are limited to 64 automation lanes. [AUTOMATION] [/AUTOMATION] # COMMENT ######### # This section will be readable from Hapax. [COMMENT] [/COMMENT]