VERSION 1 ########################################################## # __ __ __ __ __ # # .--------|__|--| |__| .-----.--.--|__|--| |-----. # # | | | _ | |__| _ | | | | _ | -__| # # |__|__|__|__|_____|__|__|___ |_____|__|_____|_____| # # |_____| # # # ########################################################## # Generated for HapaxOS 3.22 on 2026-10-22 by https://midi.guide, # the open, 'comprehensive' dataset of all MIDI CCs and NRPNs. # Contributions welcome! # TRACKNAME ########### # Supports all alphanumeric ASCII, and ' ', '_', '-', '+'. Can also be NULL. TRACKNAME OB-X8 # TYPE ###### # Can be POLY, DRUM, MPE, AFTR, POLYAT or NULL # POLY refers to polyphony, i.e. more than one note. Used for standard MIDI # gear and controllers. Confusingly, this is appropriate for instruments # and controllers that do not support poly aftertouch. # # POLYAT and AFTR are exchangeable, and both handle poly aftertouch as well as # channel aftertouch. TYPE NULL # OUTPORT ######### # Can be A, B, C, D, USBD, USBH, USBD[1-16] (virtual MIDI cable), # USBH[1-16] (virtual MIDI cable), CVG[1-4], CV[1-4], G[1-4], or NULL. OUTPORT NULL # OUTCHAN ######### # Can be a value between 1 and 16, or NULL. This is ignored if output port is # not MIDI. OUTCHAN NULL # INPORT ######## # Can be NONE, ALLACTIVE, A, B, C, D, USBD, USBH, USBD[1-16] (virtual MIDI # cable), USBH[1-16] (virtual MIDI cable), CVG[1-4], CV[1-4], G[1-4], or NULL. INPORT NULL # INCHAN ######## # Can be a value between 1 and 16, ALL, or NULL. This definition will be ignored # if INPORT is NONE, ALLACTIVE or CVG. INCHAN NULL # MAXRATE ######### # This defines the default MAXRATE for automation lanes. # Can be NULL, 192, 96, 64, 48, 32, 24, 16, 12, 8, 6, 4, 3, 2, 1 MAXRATE NULL # DRUMLANES ########### # Syntax: ROW:TRIG:CHAN:NOTENUMBER NAME # - ROW must be between 1 and 16 # - TRIG can be between 0 and 127, or NULL # - CHAN can be a number between 1 and 16, CVG[1-4], CV[1-4], G[1-4], or NULL # - NOTENUMBER can be between 0 and 127, or NULL # - NAME supports all alphanumeric ASCII, and ' ', '_', '-', '+'. It can # also be NULL # # This section will be discarded for tracks which are not DRUM tracks. [DRUMLANES] [/DRUMLANES] # PC #### # Syntax: NUMBER NAME # - NUMBER must be either a number (for simple PC), or three numbers, # delimited by ':', which represent PC:MSB:LSB. You can put 'NULL' # to not set the MSB/LSB # - PC must be between 1...128 # - MSB and LSB, if set, must be between 0...127 [PC] [/PC] # CC #### # Syntax: CC_NUMBER NAME or CC_NUMBER:DEFAULT=xx NAME # - DEFAULT_VALUE must be between 0 and 127 [CC] 1 MOD BOX LFO2 Bend Amount 3 Vintage 5 Portamento Rate 6 Data Entry MSB 7 Master Volume 8 Program Volume 9 Transpose UP Down 10 Page2 Panwidth 11 Expresion Pedal 12 OSC1 Xmod 13 OSC1 Filter ENV MOD 14 Page2 OSC Xmod AMT 15 OSC1 Freq 16 OSC2 Freq 17 OSC2 Detune 18 Page2 Voice Detune Range 19 OSC1 Waveform 20 OSC2 Waveform 21 OSC1 PW 22 OSC2 PW 23 OSC Square Mode 24 OSC1 Sync 25 OSC1 Level 26 OSC2 Level 27 Page2 OSC1 ON Level 28 Page2 OSC2 ON Level 29 Noise Level 30 Page2 Noise ON Level 31 Filter Modulation 32 Bank Select LSB 33 Filter Frequency 34 Filter Resonance 35 Filter Type 36 Filter Keyboard 37 Page2 Filter KBD ON Level 38 Data Entry LSB 39 Filter ENV Attack 40 Filter ENV Decay 41 Filter ENV Sustain 42 Filter ENV Release 43 Filter ENV Velocity ON OFF 44 Filter Pressure 45 Volume ENV Attack 46 Volume ENV Decay 47 Volume ENV Sustain 48 Volume ENV Release 49 Volume ENV Velocity ON OFF 50 ENV Type 51 LFO1 Rate 52 LFO1 Shape 53 LFO1 Depth1 54 LFO1 Depth2 55 LFO1 Dest1 OSC1 56 LFO1 Dest1 OSC2 57 LFO1 Dest1 Filter 58 LFO1 Dest2 PWM1 59 LFO1 Dest2 PWM2 60 LFO1 Dest2 Volume 61 LFO Pressure 62 Page2 LFO Type 63 Page2 LFO Sample Hold IN 64 Sustain 70 Unison 71 Unison Voice Count 72 Unison KEY Mode 73 Page2 Pedal Release 74 Brightness Filter Cutoff Relative 75 MOD BOX LFO2 Rate 76 MOD BOX LFO2 Shape 77 MOD BOX LFO2 Dest OSC1 78 MOD BOX LFO2 Dest OSC2 79 MOD BOX LFO2 Depth 80 MOD BOX LFO2 Bend OSC2 Only 81 MOD BOX Mode 82 MOD Boxlfo2 Lower 83 MOD BOX LFO2 Upper 84 MOD Boxarp ON 85 MOD Boxarp Speed 86 MOD Boxarp Hold KBD 87 MOD BOX ARP Down UP 88 MOD BOX ARP Lower 89 MOD BOX ARP Upper 90 ARP Transpose 91 Page2 Portamento Mode 92 Page2 Portamento Match 93 Page2 Portamento Quantize 94 Page2 Portamento Legato 95 Lower Upper NO Select 96 Data Increment 97 Data Decrement 98 Nrpn LSB 99 Nrpn MSB 100 RPN LSB 101 RPN MSB 102 Page2 LFO1 Trigger 103 Page2 LFO1 Trigger Phase 104 Page2 LFO1 KBD Track 105 Page2 LFO1 MOD1 Ramp Delay 106 Page2 LFO1 MOD1 Ramp UP 107 Page2 LFO1 Ramp Invert 108 Page2 LFO1 MOD1 Quantize 109 Page2 LFO1 OSC1 MOD1 Invert 110 Page2 LFO1 MOD2 Ramp Delay 111 Page2 LFO1 MOD2 Ramp UP 112 Page2 LFO1 MOD2 Ramp Invert 113 Page2 LFO1 MOD2 Quantize 114 Page2 LFO1 OSC1 MOD2 Invert 115 Page2 MOD2 Ramp TO LFO Speed 116 Page2 LFO Shift Voices58 117 Page2 Chord KEY Limit 118 Page2 Chord Hold Mode 119 Normal Split Double Mode 120 ALL Sound OFF 121 Reset Controllers 122 Local Control ON OFF 123 ALL Notes OFF 124 Omni Mode OFF 125 Omni Mode ON 126 Mono Mode ON 127 Poly Mode ON [/CC] # CC_PAIR ######### # Syntax: CC_MSB:CC_LSB NAME or CC_MSB:CC_\LSB:DEFAULT=xx NAME # - DEFAULT_VALUE must be between 0 and 16383 [CC_PAIR] [/CC_PAIR] # NRPN ###### # Syntax: MSB:LSB:DEPTH NAME or MSB:LSB:DEPTH:DEFAULT=xx NAME # - MSB and LSB should be between 0 and 127 # - LSB can be over 127 ONLY if MSB is either 0 or omitted. For example: # "0:1026:7 FOO" or ":2000:7 BAR" # These examples are equivalent to "8:2:7 FOO" and "15:80:7 BAR" # - DEPTH can be 7 or 14 # - DEFAULT_VALUE must be between 0 and 127 (for 7-bit NRPNs) or # between 0 and 16383 (for 14-bit NRPNs) [NRPN] [/NRPN] # ASSIGN ######## # Syntax: POT_NUMBER TYPE:VALUE or POT_NUMBER TYPE:VALUE DEFAULT=DEFAULT_VALUE # - POT_NUMBER must be between 1 and 8 # - TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", "NRPN", # or "NULL" (this won't assign the pot) # - Non explicitly-defined pots will be considered "NULL" # # VALUE validation # - CC: VALUE must be a valid number between 0 and 119 # - PB and AT: Any text after the TYPE will be ignored # - CV: VALUE must be between 1 and 4 # - NRPN: VALUE must be MSB:LSB:DEPTH, with MSB and LSB between 0 and 127, # and DEPTH either 7 or 14 # # DEFAULT_VALUE # - CC: DEFAULT_VALUE must be between 0 and 127 # - PB: DEFAULT_VALUE must be between 0 and 16383 # - NRPN: DEFAULT_VALUE must be a number between 0 and 127 (for 7-bit NRPNs) # or between 0 and 16383 (for 14-bit NRPNs) # - CV: DEFAULT_VALUE must be either between 0 and 65535, or a voltage between # -5V and 5V, e.g. "-4.25V" or "1.7V" # # DEFAULT_VALUE will be ignored for PB and AT messages. [ASSIGN] [/ASSIGN] # AUTOMATION ############ # Syntax: TYPE:VALUE # - TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", or "NRPN" # # VALUE validation # - CC: VALUE must be between 0 and 119 # - PB and AT: Any text after the TYPE will be ignored # - CV: VALUE must be between 1 and 4 # - NRPN: VALUE must be MSB:LSB:DEPTH, with MSB and LSB between 0 and 127, # and DEPTH either 7 or 14 # # You are limited to 64 automation lanes. [AUTOMATION] [/AUTOMATION] # COMMENT ######### # This section will be readable from Hapax. [COMMENT] [/COMMENT]