VERSION 1 ########################################################## # __ __ __ __ __ # # .--------|__|--| |__| .-----.--.--|__|--| |-----. # # | | | _ | |__| _ | | | | _ | -__| # # |__|__|__|__|_____|__|__|___ |_____|__|_____|_____| # # |_____| # # # ########################################################## # Generated for HapaxOS 3.22 on 2026-11-06 by https://midi.guide, # the open, 'comprehensive' dataset of all MIDI CCs and NRPNs. # Contributions welcome! # TRACKNAME ########### # Supports all alphanumeric ASCII, and ' ', '_', '-', '+'. Can also be NULL. TRACKNAME Circuit Mono Station # TYPE ###### # Can be POLY, DRUM, MPE, AFTR, POLYAT or NULL # POLY refers to polyphony, i.e. more than one note. Used for standard MIDI # gear and controllers. Confusingly, this is appropriate for instruments # and controllers that do not support poly aftertouch. # # POLYAT and AFTR are exchangeable, and both handle poly aftertouch as well as # channel aftertouch. TYPE NULL # OUTPORT ######### # Can be A, B, C, D, USBD, USBH, USBD[1-16] (virtual MIDI cable), # USBH[1-16] (virtual MIDI cable), CVG[1-4], CV[1-4], G[1-4], or NULL. OUTPORT NULL # OUTCHAN ######### # Can be a value between 1 and 16, or NULL. This is ignored if output port is # not MIDI. OUTCHAN NULL # INPORT ######## # Can be NONE, ALLACTIVE, A, B, C, D, USBD, USBH, USBD[1-16] (virtual MIDI # cable), USBH[1-16] (virtual MIDI cable), CVG[1-4], CV[1-4], G[1-4], or NULL. INPORT NULL # INCHAN ######## # Can be a value between 1 and 16, ALL, or NULL. This definition will be ignored # if INPORT is NONE, ALLACTIVE or CVG. INCHAN NULL # MAXRATE ######### # This defines the default MAXRATE for automation lanes. # Can be NULL, 192, 96, 64, 48, 32, 24, 16, 12, 8, 6, 4, 3, 2, 1 MAXRATE NULL # DRUMLANES ########### # Syntax: ROW:TRIG:CHAN:NOTENUMBER NAME # - ROW must be between 1 and 16 # - TRIG can be between 0 and 127, or NULL # - CHAN can be a number between 1 and 16, CVG[1-4], CV[1-4], G[1-4], or NULL # - NOTENUMBER can be between 0 and 127, or NULL # - NAME supports all alphanumeric ASCII, and ' ', '_', '-', '+'. It can # also be NULL # # This section will be discarded for tracks which are not DRUM tracks. [DRUMLANES] [/DRUMLANES] # PC #### # Syntax: NUMBER NAME # - NUMBER must be either a number (for simple PC), or three numbers, # delimited by ':', which represent PC:MSB:LSB. You can put 'NULL' # to not set the MSB/LSB # - PC must be between 1...128 # - MSB and LSB, if set, must be between 0...127 [PC] [/PC] # CC #### # Syntax: CC_NUMBER NAME or CC_NUMBER:DEFAULT=xx NAME # - DEFAULT_VALUE must be between 0 and 127 [CC] 95 Type 94 Level 90 Attack 91 Decay 92 Sustain 73 Trigger 93 Release 69 Key tracking 83 Bypass 40 Slope 114 Overdrive 71 Resonance 84 Shape 87 Sync rate 86 Clock sync 43 Key sync 88 Waveform type 7 Master 102 Selected routing 118 Mod seq to oscillator 1 PWM 38 Mod seq to oscillator 2 PWM 119 Mod seq to amp 111 Mod seq to distortion 116 Mod seq to auxillary CV 115 Velocity to oscillator 1 pitch 107 Velocity to oscillator 1 PWM 9 Velocity to oscillator 2 pitch 36 Velocity to oscillator 2 PWM 112 Velocity to amp 113 Velocity to filter frequency 105 Velocity to distortion 89 Velocity to auxillary CV 41 Envelope to oscillator 1 PWM 33 Envelope to oscillator 2 PWM 42 Envelope to amp 103 Envelope to distortion 104 Envelope to auxillary CV 73 LFO to osillator 1 PWM 34 LFO to oscillator 2 PWM 78 LFO to amp 108 LFO to distortion 109 LFO to auxillary CV 5 Glide 70 Range 39 Pulse width 80 Waveform type 117 Keyboard octave 37 Glide 75 Range 79 Pulse width 81 Waveform type 76 Keyboard octave 110 Oscillator sync [/CC] # CC_PAIR ######### # Syntax: CC_MSB:CC_LSB NAME or CC_MSB:CC_LSB:DEFAULT=xx NAME # - DEFAULT_VALUE must be between 0 and 16383 [CC_PAIR] 16:48 Frequency 18:50 Rate 22:54 Sub oscillator level 25:57 Audio in level 23:55 Noise level 24:56 Ring mod level 20:52 Oscillator 1 level 21:53 Oscillator 2 level 15:47 Mod seq to oscillator 1 pitch 19:51 Mod seq to oscillator 2 pitch 31:63 Mod seq to filter frequency 12:44 Envelope to oscillator 1 pitch 13:45 Envelope to oscillator 2 pitch 14:46 Envelope to filter frequency 28:60 LFO to oscillator 1 pitch 3:35 LFO to oscillator 2 pitch 17:49 LFO to filter frequency 26:58 Tune fine 27:59 Tune coarse 29:61 Tune fine 30:62 Tune coarse 64:2 Category [/CC_PAIR] # NRPN ###### # Syntax: MSB:LSB:DEPTH NAME or MSB:LSB:DEPTH:DEFAULT=xx NAME # - MSB and LSB should be between 0 and 127 # - LSB can be over 127 ONLY if MSB is either 0 or omitted. For example: # "0:1026:7 FOO" or ":2000:7 BAR" # These examples are equivalent to "8:2:7 FOO" and "15:80:7 BAR" # - DEPTH can be 7 or 14 # - DEFAULT_VALUE must be between 0 and 127 (for 7-bit NRPNs) or # between 0 and 16383 (for 14-bit NRPNs) [NRPN] [/NRPN] # ASSIGN ######## # Syntax: POT_NUMBER TYPE:VALUE or POT_NUMBER TYPE:VALUE DEFAULT=DEFAULT_VALUE # - POT_NUMBER must be between 1 and 8 # - TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", "NRPN", # or "NULL" (this won't assign the pot) # - Non explicitly-defined pots will be considered "NULL" # # VALUE validation # - CC: VALUE must be a valid number between 0 and 119 # - PB and AT: Any text after the TYPE will be ignored # - CV: VALUE must be between 1 and 4 # - NRPN: VALUE must be MSB:LSB:DEPTH, with MSB and LSB between 0 and 127, # and DEPTH either 7 or 14 # # DEFAULT_VALUE # - CC: DEFAULT_VALUE must be between 0 and 127 # - PB: DEFAULT_VALUE must be between 0 and 16383 # - NRPN: DEFAULT_VALUE must be a number between 0 and 127 (for 7-bit NRPNs) # or between 0 and 16383 (for 14-bit NRPNs) # - CV: DEFAULT_VALUE must be either between 0 and 65535, or a voltage between # -5V and 5V, e.g. "-4.25V" or "1.7V" # # DEFAULT_VALUE will be ignored for PB and AT messages. [ASSIGN] [/ASSIGN] # AUTOMATION ############ # Syntax: TYPE:VALUE # - TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", or "NRPN" # # VALUE validation # - CC: VALUE must be between 0 and 119 # - PB and AT: Any text after the TYPE will be ignored # - CV: VALUE must be between 1 and 4 # - NRPN: VALUE must be MSB:LSB:DEPTH, with MSB and LSB between 0 and 127, # and DEPTH either 7 or 14 # # You are limited to 64 automation lanes. [AUTOMATION] [/AUTOMATION] # COMMENT ######### # This section will be readable from Hapax. [COMMENT] [/COMMENT]