VERSION 1 ########################################################## # __ __ __ __ __ # # .--------|__|--| |__| .-----.--.--|__|--| |-----. # # | | | _ | |__| _ | | | | _ | -__| # # |__|__|__|__|_____|__|__|___ |_____|__|_____|_____| # # |_____| # # # ########################################################## # Generated on 2026-04-17 by https://midi.guide , the open, # 'comprehensive' dataset of all MIDI CCs and NRPNs. # Contributions welcome! # Supports all alphanumeric ASCII, and ' ', '_', '-', '+' - can also be NULL TRACKNAME Sub Phatty # Can be POLY, DRUM, MPE, or NULL TYPE NULL # Can be A, B, C, D, USBD, USBH, CVGx (x between 1&4), CVx, Gx, or NULL OUTPORT NULL # Can be x (between 1-16), or NULL -- this is ignored if output port is not MIDI OUTCHAN NULL # Can be NONE, ALLACTIVE, A, B, USBH, USBD, CVG, or NULL INPORT NULL # Can be x (between 1-16), ALL, or NULL. This definition will be ignored if INPORT is NONE, ALLACTIVE or CVG INCHAN NULL # This defines the default 'MAX RATE' for automation lanes. # Can be NULL, 192, 96, 64, 48, 32, 24, 16, 12, 8, 6, 4, 3, 2, 1 MAXRATE NULL # DRUMLANES # Syntax: ROW:TRIG:CHAN:NOTENUMBER NAME # ROW must be between 1 and 8 # TRIG can be between 0 and 127, or NULL # CHAN can be a number between 1 and 16, Gx, CVx, CVGx (x between 1 and 4), or NULL # NOTENUMBER can be between 0 and 127, or NULL # NAME supports all alphanumeric ASCII, and ' ', '_', '-', '+' - can also be NULL # Please note this section will be discarded for tracks which are not DRUM tracks [DRUMLANES] [/DRUMLANES] # PC # Syntax: NUMBER NAME # number must be either: # - A number (for simple PC) # - Three numbers, delimited by ':', which represent PC:MSB:LSB. You can put 'NULL' to not set the MSB/LSB. # PC must be between 1...128 # MSB/LSB must be between 0...127 [PC] [/PC] # CC # Syntax: CC_NUMBER NAME or CC_NUMBER:DEFAULT=xx NAME # DEFAULT_VALUE must be a valid number between 0 and 127 [CC] 115 Amplifier EG trigger mode 83 Amplifier EG reset 92 Amplifier EG velocity to amplitude 80 Amplifier EG KB amount 106 Amplifier EG hold 113 Amplifier EG repeat 104 Amplifier EG delay 87 Amplifier EG velocity to time 109 Filter poles 110 Filter EG velocity to amplitude 105 Filter EG hold 112 Filter EG repeat 86 Filter EG velocity to time 79 Filter EG KB amount 90 Filter EG gate source 103 Filter EG delay 114 Filter EG trigger mode 82 Filter EG reset 72 Wave mod destination 68 Legato 119 Keyboard transpose 91 Volume EG gate source 111 Note priority 88 Release on off 71 Modulation source 107 Pitch bend up 108 Pitch bend down 89 Keyboard octave 116 External input level 1 Modulation wheel 85 Glide type 65 Glide on off 94 Glide legato 73 Gated glide 93 LFO gate reset 76 LFO range 78 LFO KB tracking amount 102 LFO MIDI sync 81 VCO gate reset 77 VCO 2 hard sync 75 VCO 2 octave 74 VCO 1 octave 70 Pitch mod oscillator 2 only [/CC] # CC Pair # Syntax: CC_MSB:CC_LSB NAME or CC_MSB:CC_LSB:DEFAULT=xx NAME # DEFAULT_VALUE must be a valid number between 0 and 16383 [CC_PAIR] 29:61 Amplifier EG decay 30:62 Amplifier EG sustain 31:63 Amplifier EG release 28:60 Amplifier EG attack 19:51 Filter cutoff frequency 27:59 Filter KB tracking amount 21:53 Filter resonance 22:54 Filter EG amount 23:55 Filter EG attack 24:56 Filter EG decay 25:57 Filter EG sustain 26:58 Filter EG release 18:50 Multidrive amount 2:34 Filter mod amount 4:36 Pitch mod amount 20:52 Wave mod amount 7:39 Output level 5:37 Glide rate 3:35 LFO rate 13:45 VCO 2 beat frequency 12:44 VCO 2 frequency 14:46 VCO 2 wave 9:41 VCO 1 wave 17:49 VCO 1 sub level 8:40 Noise level 16:48 VCO 2 level 15:47 VCO 1 level [/CC_PAIR] # NRPN # Syntax: "MSB:LSB:DEPTH NAME" or "MSB:LSB:DEPTH:DEFAULT=xx NAME" # Lsb & msb should be between 0 and 127 # Note: LSB can be over 127 ONLY if MSB is 0 or omitted # e.g. '0:1026:7 FOO', or ':2000:7 BAR' # the examples above would be equivalent to '8:2:7 FOO' and '15:80:7 BAR' respectively # DEPTH can be 7 or 14 # For NRPN: DEFAULT_VALUE must be a valid number, either between 0 and 127 (for 7 bit NRPNs) or between 0 and 16383 (for 14bit NRPNs) [NRPN] [/NRPN] # ASSIGN # Syntax: POT_NUMBER TYPE:VALUE or POT_NUMBER TYPE:VALUE DEFAULT=DEFAULT_VALUE # POT_NUMBER must be between 1 and 8 # TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", "NRPN", or "NULL" (this won't assign the pot). # Non explicitly-defined pots will be considered "NULL" # VALUE VALIDATION #### For CC: Value must be a valid number between 0 and 119 #### For PB and AT, any text after the TYPE will be ignored #### For CV, value must be between 1 and 4 #### For NRPN, value must be MSB:LSB:DEPTH, with both lsb & msb bebtween 0 and 127, and DEPTH being either 7 or 14 # DEFAULT VALUE #### For CC: DEFAULT_VALUE must be a valid number between 0 and 127 #### For PB: DEFAULT_VALUE must be a valid number between 0 and 16383 #### For NRPN: DEFAULT_VALUE must be a valid number, either between 0 and 127 (for 7 bit NRPNs) or between 0 and 16383 (for 14bit NRPNs) #### For CV: DEFAULT_VALUE must be either a valid number between 0 and 65535, or a voltage between -5V and 5V, e.g. "-4.25V" or "1.7V" #### Please note default value will be ignored for PB and AT messages. [ASSIGN] [/ASSIGN] # AUTOMATION # Syntax: TYPE:VALUE # TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", or "NRPN" # VALUE VALIDATION #### For CC: Value must be a valid number between 0 and 119 #### For PB and AT, any text after the TYPE will be ignored #### For CV, value must be between 1 and 4 #### For NRPN, value must be MSB:LSB:DEPTH, with both lsb & msb bebtween 0 and 127, and DEPTH being either 7 or 14 # NOTE: You are limited to 64 automation lanes [AUTOMATION] [/AUTOMATION] # This section will be readable from Hapax. [COMMENT] [/COMMENT]