VERSION 1 # Supports all alphanumeric ASCII, and ' ', '_', '-', '+' - can also be NULL TRACKNAME Prophet X Prophet XL # Can be POLY, DRUM, MPE, or NULL TYPE NULL # Can be A, B, C, D, USBD, USBH, CVGx (x between 1&4), CVx, Gx, or NULL OUTPORT NULL # Can be x (between 1-16), or NULL -- this is ignored if output port is not MIDI OUTCHAN NULL # Can be NONE, ALLACTIVE, A, B, USBH, USBD, CVG, or NULL INPORT NULL # Can be x (between 1-16), ALL, or NULL. This definition will be ignored if INPORT is NONE, ALLACTIVE or CVG INCHAN NULL # This defines the default 'MAX RATE' for automation lanes. # Can be NULL, 192, 96, 64, 48, 32, 24, 16, 12, 8, 6, 4, 3, 2, 1 MAXRATE NULL # DRUMLANES # Syntax: ROW:TRIG:CHAN:NOTENUMBER NAME # ROW must be between 1 and 8 # TRIG can be between 0 and 127, or NULL # CHAN can be a number between 1 and 16, Gx, CVx, CVGx (x between 1 and 4), or NULL # NOTENUMBER can be between 0 and 127, or NULL # NAME supports all alphanumeric ASCII, and ' ', '_', '-', '+' - can also be NULL # Please note this section will be discarded for tracks which are not DRUM tracks [DRUMLANES] [/DRUMLANES] # PC # Syntax: NUMBER NAME # number must be either: # - A number (for simple PC) # - Three numbers, delimited by ':', which represent PC:MSB:LSB. You can put 'NULL' to not set the MSB/LSB. # PC must be between 1...128 # MSB/LSB must be between 0...127 [PC] [/PC] # CC # Syntax: CC_NUMBER NAME or CC_NUMBER:DEFAULT=xx NAME # DEFAULT_VALUE must be a valid number between 0 and 127 [CC] 1 MOD Wheel 3 BPM 5 Glide Mode 7 Master Volume 8 SUB OSC 10 PAN Spread 12 Voice Volume 13 AB Mode 14 Slider1 POS 15 Slider2 POS 16 FX1 ON OFF 17 FX1 Select 18 FX1 MIX 19 FX1 Param1 20 FX1 Param2 21 FX1 Param3 22 FX2 ON OFF 23 FX2 Select 24 FX2 MIX 25 FX2 Param1 26 FX2 Param2 27 FX2 Param3 28 16 Voice Mode 29 Split Point 32 Bank Select 40 AMP ENV Amount 41 Velocity TO AMP ENV 42 AMP ENV Delay 43 AMP ENV Attack 44 AMP ENV Decay 45 AMP ENV Sustain 46 AMP ENV Release 47 Filter ENV Amount 48 Velocity TO Filter ENV 49 Filter ENV Delay 50 Filter ENV Attack 51 Filter ENV Decay 52 Filter ENV Sustain 53 Filter ENV Release 54 Inst1 Glide Amount 55 Inst2 Glide Amount 56 OSC1 Glide Amount 57 OSC2 Glide Amount 58 Arpeggiator ON OFF 59 Arpeggiator Mode 60 Arpeggiator Range 61 Arpeggiator Relatch 62 Clock Divide 63 Arpeggiator Repeats 64 Sustain Pedal 65 Glide ON OFF 66 Inst1 Freq 67 Inst1 Fine Tune 68 Inst1 Level 69 Inst1 PAN 70 Inst1 Loop ON OFF 71 Inst1 Reverse 72 Inst2 Freq 73 Inst2 Fine TUN 75 Inst2 Level 76 Inst2 PAN 77 Inst2 Loop ON 78 Inst2 Reverse 79 Osc21 Sync 80 OSC1 FRQ 81 OSC1 Fine Freq 82 OSC1 Level 83 OSC1 Shape 84 OSC1 Shape MOD 85 OSC1 PAN 86 OSC2 FRQ 87 OSC2 Fine Freq 88 OSC2 Level 89 OSC2 Shape 90 OSC2 Shape MOD 91 OSC2 PAN 92 OSC Slop 93 Hack 94 Decimate 102 Cutoff 103 Reso 104 Filt Keyb Amount 105 Drive 106 LP Stereo Split 116 Unison ON OFF 117 Unison Detune 118 Unison Mode [/CC] # CC Pair # Syntax: CC_MSB:CC_LSB NAME or CC_MSB:CC_LSB:DEFAULT=xx NAME # DEFAULT_VALUE must be a valid number between 0 and 16383 [CC_PAIR] [/CC_PAIR] # NRPN # Syntax: "MSB:LSB:DEPTH NAME" or "MSB:LSB:DEPTH:DEFAULT=xx NAME" # Lsb & msb should be between 0 and 127 # Note: LSB can be over 127 ONLY if MSB is 0 or omitted # e.g. '0:1026:7 FOO', or ':2000:7 BAR' # the examples above would be equivalent to '8:2:7 FOO' and '15:80:7 BAR' respectively # DEPTH can be 7 or 14 # For NRPN: DEFAULT_VALUE must be a valid number, either between 0 and 127 (for 7 bit NRPNs) or between 0 and 16383 (for 14bit NRPNs) [NRPN] [/NRPN] # ASSIGN # Syntax: POT_NUMBER TYPE:VALUE or POT_NUMBER TYPE:VALUE DEFAULT=DEFAULT_VALUE # POT_NUMBER must be between 1 and 8 # TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", "NRPN", or "NULL" (this won't assign the pot). # Non explicitly-defined pots will be considered "NULL" # VALUE VALIDATION #### For CC: Value must be a valid number between 0 and 119 #### For PB and AT, any text after the TYPE will be ignored #### For CV, value must be between 1 and 4 #### For NRPN, value must be MSB:LSB:DEPTH, with both lsb & msb bebtween 0 and 127, and DEPTH being either 7 or 14 # DEFAULT VALUE #### For CC: DEFAULT_VALUE must be a valid number between 0 and 127 #### For PB: DEFAULT_VALUE must be a valid number between 0 and 16383 #### For NRPN: DEFAULT_VALUE must be a valid number, either between 0 and 127 (for 7 bit NRPNs) or between 0 and 16383 (for 14bit NRPNs) #### For CV: DEFAULT_VALUE must be either a valid number between 0 and 65535, or a voltage between -5V and 5V, e.g. "-4.25V" or "1.7V" #### Please note default value will be ignored for PB and AT messages. [ASSIGN] [/ASSIGN] # AUTOMATION # Syntax: TYPE:VALUE # TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", or "NRPN" # VALUE VALIDATION #### For CC: Value must be a valid number between 0 and 119 #### For PB and AT, any text after the TYPE will be ignored #### For CV, value must be between 1 and 4 #### For NRPN, value must be MSB:LSB:DEPTH, with both lsb & msb bebtween 0 and 127, and DEPTH being either 7 or 14 # NOTE: You are limited to 64 automation lanes [AUTOMATION] [/AUTOMATION] # This section will be readable from Hapax. [COMMENT] [/COMMENT]