BOSS GT-1000 MIDI CCs & NRPNs

Aside from Bank Select as documented here, the GT-1000 (like the GT-1000CORE) has no fixed default CC targets. CC#1-31 and CC#64-95 are recognized once MENU > ASSIGN SETTING > SOURCE is set to that CC number by the user and mapped to a target parameter and range.

Last update: September 22, 2026 • 2 parameters


Contributions welcome! You can email us your edited CSV if you don't want to use GitHub.

Banks and presets

Parameter CC Range Usage Description Orientation
Bank Select MSB 0 [0–2]
Selects the patch bank. Combine with a Program Change to recall a patch
Note: GT-1000 starts up on bank 0 until a Bank Select message is received.
0-based
Bank Select LSB 32 [0–0]
Note: Always 0 on this unit
0-based