VERSION 1 ########################################################## # __ __ __ __ __ # # .--------|__|--| |__| .-----.--.--|__|--| |-----. # # | | | _ | |__| _ | | | | _ | -__| # # |__|__|__|__|_____|__|__|___ |_____|__|_____|_____| # # |_____| # # # ########################################################## # Generated for HapaxOS 3.2.2 on 2026-10-21 by https://midi.guide, # the open, 'comprehensive' dataset of all MIDI CCs and NRPNs. # Contributions welcome! # TRACKNAME ########### # Supports all alphanumeric ASCII, and ' ', '_', '-', '+'. Can also be NULL. TRACKNAME Thyme+ # TYPE ###### # Can be POLY, DRUM, MPE, AFTR, POLYAT or NULL # POLY refers to polyphony, i.e. more than one note. Used for standard MIDI # gear and controllers. Confusingly, this is appropriate for instruments # and controllers that do not support poly aftertouch. # # POLYAT and AFTR are exchangeable, and both handle poly aftertouch as well as # channel aftertouch. TYPE NULL # OUTPORT ######### # Can be A, B, C, D, USBD, USBH, USBD[1-16] (virtual MIDI cable), # USBH[1-16] (virtual MIDI cable), CVG[1-4], CV[1-4], G[1-4], or NULL. OUTPORT NULL # OUTCHAN ######### # Can be a value between 1 and 16, or NULL. This is ignored if output port is # not MIDI. OUTCHAN NULL # INPORT ######## # Can be NONE, ALLACTIVE, A, B, C, D, USBD, USBH, USBD[1-16] (virtual MIDI # cable), USBH[1-16] (virtual MIDI cable), CVG[1-4], CV[1-4], G[1-4], or NULL. INPORT NULL # INCHAN ######## # Can be a value between 1 and 16, ALL, or NULL. This definition will be ignored # if INPORT is NONE, ALLACTIVE or CVG. INCHAN NULL # MAXRATE ######### # This defines the default MAXRATE for automation lanes. # Can be NULL, 192, 96, 64, 48, 32, 24, 16, 12, 8, 6, 4, 3, 2, 1 MAXRATE NULL # DRUMLANES ########### # Syntax: ROW:TRIG:CHAN:NOTENUMBER NAME # - ROW must be between 1 and 16 # - TRIG can be between 0 and 127, or NULL # - CHAN can be a number between 1 and 16, CVG[1-4], CV[1-4], G[1-4], or NULL # - NOTENUMBER can be between 0 and 127, or NULL # - NAME supports all alphanumeric ASCII, and ' ', '_', '-', '+'. It can # also be NULL # # This section will be discarded for tracks which are not DRUM tracks. [DRUMLANES] [/DRUMLANES] # PC #### # Syntax: NUMBER NAME # - NUMBER must be either a number (for simple PC), or three numbers, # delimited by ':', which represent PC:MSB:LSB. You can put 'NULL' # to not set the MSB/LSB # - PC must be between 1...128 # - MSB and LSB, if set, must be between 0...127 [PC] [/PC] # CC #### # Syntax: CC_NUMBER NAME or CC_NUMBER:DEFAULT=xx NAME # - DEFAULT_VALUE must be between 0 and 127 [CC] 54 Coarse Robot Sync 46 Coarse Knob Value 47 Coarse Robot Amount 48 Coarse Robot Rate 49 Coarse Robot Shape 50 Coarse Robot Waveform 51 Coarse Robot Phase 52 Coarse Robot Polarity 53 Coarse Robot Stereo 64 Footswitch 120 Activate Bypass 90 Change Pattern 70 Delay Sync 69 Link 68 Freeze 67 Randomize Robots Tape Machine 66 Randomize Robots 65 Randomize Tape Machine 36 Feedback Robot Sync 28 Feedback Knob Value 29 Feedback Robot Amount 30 Feedback Robot Rate 31 Feedback Robot Shape 32 Feedback Robot Waveform 33 Feedback Robot Phase 34 Feedback Robot Polarity 35 Feedback Robot Stereo 39 Filter Robot Rate 40 Filter Robot Shape 41 Filter Robot Waveform 42 Filter Robot Phase 43 Filter Robot Polarity 44 Filter Robot Stereo 45 Filter Robot Sync 37 Filter Knob Value 38 Filter Robot Amount 63 Fine Robot Sync 62 Fine Robot Stereo 55 Fine Knob Value 56 Fine Robot Amount 57 Fine Robot Rate 58 Fine Robot Shape 59 Fine Robot Waveform 60 Fine Robot Phase 61 Fine Robot Polarity 77 Levels Robot Polarity 71 Levels Knob Value 72 Levels Robot Amount 73 Levels Robot Rate 74 Levels Robot Shape 75 Levels Robot Waveform 76 Levels Robot Phase 78 Levels Robot Stereo 79 Levels Robot Sync 11 Mix Robot Amount 18 Mix Robot Sync 17 Mix Robot Stereo 16 Mix Robot Polarity 15 Mix Robot Phase 14 Mix Robot Waveform 13 Mix Robot Shape 12 Mix Robot Rate 10 Mix Knob Value 81 Spacing Robot Amount 88 Spacing Robot Sync 87 Spacing Robot Stereo 86 Spacing Robot Polarity 82 Spacing Robot Rate 85 Spacing Robot Phase 84 Spacing Robot Waveform 83 Spacing Robot Shape 80 Spacing Knob Value 89 Karplus Strong Decay Time Compensation 20 Tape Speed Robot Amount 27 Tape Speed Robot Sync 26 Tape Speed Robot Stereo 25 Tape Speed Robot Polarity 24 Tape Speed Robot Phase 23 Tape Speed Robot Waveform 22 Tape Speed Robot Shape 21 Tape Speed Robot Rate 19 Tape Speed Knob Value 9 Volume Robot Sync 2 Volume Robot Amount 3 Volume Robot Rate 1 Volume Knob Value 4 Volume Robot Shape 5 Volume Robot Waveform 6 Volume Robot Phase 7 Volume Robot Polarity 8 Volume Robot Stereo [/CC] # CC_PAIR ######### # Syntax: CC_MSB:CC_LSB NAME or CC_MSB:CC_\LSB:DEFAULT=xx NAME # - DEFAULT_VALUE must be between 0 and 16383 [CC_PAIR] [/CC_PAIR] # NRPN ###### # Syntax: MSB:LSB:DEPTH NAME or MSB:LSB:DEPTH:DEFAULT=xx NAME # - MSB and LSB should be between 0 and 127 # - LSB can be over 127 ONLY if MSB is either 0 or omitted. For example: # "0:1026:7 FOO" or ":2000:7 BAR" # These examples are equivalent to "8:2:7 FOO" and "15:80:7 BAR" # - DEPTH can be 7 or 14 # - DEFAULT_VALUE must be between 0 and 127 (for 7-bit NRPNs) or # between 0 and 16383 (for 14-bit NRPNs) [NRPN] [/NRPN] # ASSIGN ######## # Syntax: POT_NUMBER TYPE:VALUE or POT_NUMBER TYPE:VALUE DEFAULT=DEFAULT_VALUE # - POT_NUMBER must be between 1 and 8 # - TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", "NRPN", # or "NULL" (this won't assign the pot) # - Non explicitly-defined pots will be considered "NULL" # # VALUE validation # - CC: VALUE must be a valid number between 0 and 119 # - PB and AT: Any text after the TYPE will be ignored # - CV: VALUE must be between 1 and 4 # - NRPN: VALUE must be MSB:LSB:DEPTH, with MSB and LSB between 0 and 127, # and DEPTH either 7 or 14 # # DEFAULT_VALUE # - CC: DEFAULT_VALUE must be between 0 and 127 # - PB: DEFAULT_VALUE must be between 0 and 16383 # - NRPN: DEFAULT_VALUE must be a number between 0 and 127 (for 7-bit NRPNs) # or between 0 and 16383 (for 14-bit NRPNs) # - CV: DEFAULT_VALUE must be either between 0 and 65535, or a voltage between # -5V and 5V, e.g. "-4.25V" or "1.7V" # # DEFAULT_VALUE will be ignored for PB and AT messages. [ASSIGN] [/ASSIGN] # AUTOMATION ############ # Syntax: TYPE:VALUE # - TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", or "NRPN" # # VALUE validation # - CC: VALUE must be between 0 and 119 # - PB and AT: Any text after the TYPE will be ignored # - CV: VALUE must be between 1 and 4 # - NRPN: VALUE must be MSB:LSB:DEPTH, with MSB and LSB between 0 and 127, # and DEPTH either 7 or 14 # # You are limited to 64 automation lanes. [AUTOMATION] [/AUTOMATION] # COMMENT ######### # This section will be readable from Hapax. [COMMENT] [/COMMENT]