VERSION 1 # Supports all alphanumeric ASCII, and ' ', '_', '-', '+' - can also be NULL TRACKNAME Virus A # Can be POLY, DRUM, MPE, or NULL TYPE NULL # Can be A, B, C, D, USBD, USBH, CVGx (x between 1&4), CVx, Gx, or NULL OUTPORT NULL # Can be x (between 1-16), or NULL -- this is ignored if output port is not MIDI OUTCHAN NULL # Can be NONE, ALLACTIVE, A, B, USBH, USBD, CVG, or NULL INPORT NULL # Can be x (between 1-16), ALL, or NULL. This definition will be ignored if INPORT is NONE, ALLACTIVE or CVG INCHAN NULL # This defines the default 'MAX RATE' for automation lanes. # Can be NULL, 192, 96, 64, 48, 32, 24, 16, 12, 8, 6, 4, 3, 2, 1 MAXRATE NULL # DRUMLANES # Syntax: ROW:TRIG:CHAN:NOTENUMBER NAME # ROW must be between 1 and 8 # TRIG can be between 0 and 127, or NULL # CHAN can be a number between 1 and 16, Gx, CVx, CVGx (x between 1 and 4), or NULL # NOTENUMBER can be between 0 and 127, or NULL # NAME supports all alphanumeric ASCII, and ' ', '_', '-', '+' - can also be NULL # Please note this section will be discarded for tracks which are not DRUM tracks [DRUMLANES] [/DRUMLANES] # PC # Syntax: NUMBER NAME # number must be either: # - A number (for simple PC) # - Three numbers, delimited by ':', which represent PC:MSB:LSB. You can put 'NULL' to not set the MSB/LSB. # PC must be between 1...128 # MSB/LSB must be between 0...127 [PC] [/PC] # CC # Syntax: CC_NUMBER NAME or CC_NUMBER:DEFAULT=xx NAME # DEFAULT_VALUE must be a valid number between 0 and 127 [CC] 60 Amp env decay 59 Amp env attack 58 Filter env release 55 Filter env decay 56 Filter env sustain 57 Filter env sustain time 63 Amp env release 54 Filter env attack 62 Amp env sustain time 61 Amp env sustain 47 Filter2 keyfollow 48 Filter balance 51 Filter1 mode 53 Filter routing 52 Filter2 mode 40 Cutoff 41 Cutoff2 42 Filter1 resonance 43 Filter2 resonance 44 Filter1 env amt 45 Filter2 env amt 46 Filter1 keyfollow 118 Delay lfo shape 114 Delay time 113 Effect send 110 Chorus lfo shape 109 Chorus feedback 108 Chorus delay 107 Chorus depth 106 Chorus rate 105 Chorus mix 115 Delay feedback 117 Delay depth 116 Delay rate 123 All notes off 5 Portamento time 7 Channel volume 10 Panorama 30 Fm filt env amt 31 Osc2 keyfollow 32 Bank select 49 Saturation curve 64 Hold pedal 91 Patch volume 93 Transpose 94 Key mode 97 Twin mode 98 Twin detune 99 Panorama spread 101 Input mode 102 Input select 1 Modulation wheel 81 Lfo2 env mode 71 Lfo1 symmetry 72 Lfo1 keyfollow amt 74 Osc1 lfo1 amount 75 Osc2 lfo1 amount 76 Pw lfo1 amount 77 Reso lfo1 amount 78 Filtgain lfo1 amount 79 Lfo2 rate 80 Lfo2 shape 70 Lfo1 mode 82 Lfo2 mode 83 Lfo2 symmetry 85 Lfo2 keytrigger 86 Oscshape lfo2 amount 87 Fmamount lfo2 amount 88 Cutoff1 lfo2 amount 89 Cutoff2 lfo2 amount 90 Panorama lfo2 amount 100 Twin lfo phase 67 Lfo1 rate 68 Lfo1 shape 69 Lfo1 env mode 37 Noise volume 34 Suboscillator volume 33 Osc balance 36 Osc main volume 17 Osc1 shape 28 Osc2 sync 27 Osc2 fm amount 26 Osc2 detune 35 Suboscillator shape 29 Osc2 filt env amt 24 Osc2 wave select 23 Osc2 pulsewidth 22 Osc2 shape 20 Osc1 semitone 21 Osc1 keyfollow 19 Osc1 wave select 25 Osc2 semitone 18 Osc1 pulsewidth [/CC] # CC Pair # Syntax: CC_MSB:CC_LSB NAME or CC_MSB:CC_LSB:DEFAULT=xx NAME # DEFAULT_VALUE must be a valid number between 0 and 16383 [CC_PAIR] [/CC_PAIR] # NRPN # Syntax: "MSB:LSB:DEPTH NAME" or "MSB:LSB:DEPTH:DEFAULT=xx NAME" # Lsb & msb should be between 0 and 127 # Note: LSB can be over 127 ONLY if MSB is 0 or omitted # e.g. '0:1026:7 FOO', or ':2000:7 BAR' # the examples above would be equivalent to '8:2:7 FOO' and '15:80:7 BAR' respectively # DEPTH can be 7 or 14 # For NRPN: DEFAULT_VALUE must be a valid number, either between 0 and 127 (for 7 bit NRPNs) or between 0 and 16383 (for 14bit NRPNs) [NRPN] [/NRPN] # ASSIGN # Syntax: POT_NUMBER TYPE:VALUE or POT_NUMBER TYPE:VALUE DEFAULT=DEFAULT_VALUE # POT_NUMBER must be between 1 and 8 # TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", "NRPN", or "NULL" (this won't assign the pot). # Non explicitly-defined pots will be considered "NULL" # VALUE VALIDATION #### For CC: Value must be a valid number between 0 and 119 #### For PB and AT, any text after the TYPE will be ignored #### For CV, value must be between 1 and 4 #### For NRPN, value must be MSB:LSB:DEPTH, with both lsb & msb bebtween 0 and 127, and DEPTH being either 7 or 14 # DEFAULT VALUE #### For CC: DEFAULT_VALUE must be a valid number between 0 and 127 #### For PB: DEFAULT_VALUE must be a valid number between 0 and 16383 #### For NRPN: DEFAULT_VALUE must be a valid number, either between 0 and 127 (for 7 bit NRPNs) or between 0 and 16383 (for 14bit NRPNs) #### For CV: DEFAULT_VALUE must be either a valid number between 0 and 65535, or a voltage between -5V and 5V, e.g. "-4.25V" or "1.7V" #### Please note default value will be ignored for PB and AT messages. [ASSIGN] [/ASSIGN] # AUTOMATION # Syntax: TYPE:VALUE # TYPE can be "CC", "PB" (pitchbend), "AT" (aftertouch), "CV", or "NRPN" # VALUE VALIDATION #### For CC: Value must be a valid number between 0 and 119 #### For PB and AT, any text after the TYPE will be ignored #### For CV, value must be between 1 and 4 #### For NRPN, value must be MSB:LSB:DEPTH, with both lsb & msb bebtween 0 and 127, and DEPTH being either 7 or 14 # NOTE: You are limited to 64 automation lanes [AUTOMATION] [/AUTOMATION] # This section will be readable from Hapax. [COMMENT] [/COMMENT]